09-330

Fisherbrand™ Traceable™ Bench Conductivity Meter

Manufacturer: Fischer Scientific

The price for this product is unavailable. Please request a quote

Includes

115 V Power Adapter, 3 in. long (7.6 cm) Glass Probe, Receptacle to supply probe replatinizing current, 21 in. long (53.3 cm) Pivoting Probe Holder Arm, 9 V Battery

Outputs

RS232

Measurement Modes

Conductivity, Resistivity, Dissolved Solid, Salinity, Concentration, Temperature

Range (Conductivity)

0.01 μS to 200 mS

Range (TDS)

0.01 mg/L to 20 g/L

Temperature Range (English)

-22°F to +266°F

Display Type

LCD

Weight (Metric)

0.7 kg

Detection Range

0.01 μS/cm to 200 mS/cm

Height (English)

8.25 in.

Depth (Metric)

8.89 cm

Voltage

115 V

Accuracy (Conductivity)

±0.3%

For Use With (Application)

Conductivity

Calibration Points

4

Range (Salinity)

2 to 42 ppt

Temperature Range (Metric)

-30°C to +130°C

Range (Resistivity)

0.001 to 2 megohm

Certifications/Compliance

CAP, ASTM, NCCLS, ACS

Weight (English)

1.5 lb.

Accuracy

±0.3%

Height (Metric)

20.95 cm

Battery Type

9 V

Related Products

Img

Fischer Scientific

06-662-66

--

Img

Fischer Scientific

01-912-352

--

Img

YSI™

15-177-831

--

Img

Fischer Scientific

01-912-353

--

Img

YSI™

15-177-622

--

Img

Fischer Scientific

01-912-355

--

Img

Fischer Scientific

01-912-354

--

Img

OHAUS™

S05298

--

Description

  • Traceable™ Bench Conductivity Meter measures conductivity, resistivity, dissolved solids, salinity, concentration, and temperature; includes certificate of traceability to standards provided by NIST™
  • Features six modes — conductivity, resistivity, total dissolved solids, salinity, concentration and temperature readings Ideal for ISO 9000 and government certification requirements Autorange automatically selects most appropriate range for current reading unless feature is disabled Controls allow operator to calibrate to solution standards; four calibration points ensure accuracy over entire range Automatic or manual temperature compensation is defeatable Automatic/manual temperature compensation with readings referenced to international standard of 25°C Temperature compensation disable function fulfills USP-NF (United States Pharmacopeia, National Formulary, 645 Conductivity Measurement) requirements Multiple applications plus connectivity Measures conductivity in chromatography, biology, food, electronics and water analysis Meets CAP, ASTM™, NCCLS, and ACS specifications in measuring reagent-grade water Includes certificate to indicate instrument traceability to standards provided by the National Institute of Standards and Technology; calibrated by an ISO 17025 calibration laboratory accredited by A2LA RS-232-C output allows readings to be downloaded to accessory datalogger or computer Measurement Modes and Ranges Conductivity Autoranging: 0.01 μS to 200 mS (in 5 ranges) Resistance Autoranging: 0.001 to 20.00 megohms (in 2 ranges) TDS Autoranging: 0.01 mg/L to 20.0 g/L (in 4 ranges) Temperature: -30° to +130°C (-22° to +266°F) Concentration: 0.000 to 9999 user units Salinity: 2 to 42 ppt Relative Accuracy: ±0.3% Temperature Compensation Types Automatic and manual, displays temperature °F/°C Reference Temperature (conductivity): References to international standard 25°C (77°F) Features Electronic Calibration Supplied Internal (1000 °mhos and 0.001 megohm) Data Output: RS-232-C, recorder jack Display: 0.5 in
  • digit LCD Net Weight: 1.5 lb
  • (0.7 kg) Dimensions (L x W x H): 8.25 x 6 x 3.5 in
  • (21 x 15.2 x 8.9 cm) Order Info Replacement glass probe (09-326-2A) and unbreakable epoxy plastic probe (22-278143) are sold separately.