PI16183

Thermo Scientific™ Pierce™ Cypridina-Firefly Luciferase Dual Assay Kit

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 PI16183-Each-of-1 In Stock ₹ 14,699.21

PI16183 - Each of 1

₹ 14,699.21

In Stock

Quantity

1

Base Price: ₹ 14,699.21

GST (18%): ₹ 2,645.858

Total Price: ₹ 17,345.068

Type

Assay Kit

Sufficient For

100 Dual Luciferase Assays

Content And Storage

Sufficient For: 100 dual-luciferase assays in microplate wells• Cypridina-Firefly Dual Assay Buffer, 5 mL (store at 4°C)• 100X Vargulin, 50 μL (store at -20°C)• D-Luciferin, 3 mg (store at 4°C)• Luciferase Cell Lysis Buffer (2X), 6 mL (store at room temperature)Upon receipt, store kit at -20°C, or store individual components as indicated above.

Compatible Cells

Mammalian Cells

For Use With (Equipment)

Luminometer (Microplate)

Label Type

Enzyme Labeled

Technique

Enhanced Chemiluminescence

Product Line

Pierce™

Target

Luciferase, Cypridina Luciferase

Quantity

100 Reaction Kit

Assay

Reporter Enzyme, Luciferase Reporter Assay

Detection Method

Bioluminescence

Format

384-well plate, 96-well plate

Substrate Properties

Chemical Substrate

Substrate Type

Luciferase Substrate

Substrate

Vargulin (Cypridina Luciferin), D-Luciferin

Related Products

Img

Fischer Scientific

PI16184

--

Img

Fischer Scientific

PI16185

--

Img

Fischer Scientific

PI16186

--

Img

Fischer Scientific

PI16168

--

Img

Fischer Scientific

PI16158

--

Img

Fischer Scientific

PI16169

--

Img

Fischer Scientific

PI16170

--

Img

Fischer Scientific

PI16171

--

Description

  • The Thermo Scientific™ Pierce Cypridina-Firefly Luciferase Dual Assay Kit provides the necessary reagents to simultaneously detect intracellular Cypridina and Red Firefly luciferase activity in mammalian whole cell lysates
  • The Pierce Cypridina -Firefly Luciferase Dual Assay Kit is a highly sensitive assay that allows for the simultaneous detection of Cypridina and Red Firefly luciferase activity
  • Cypridina luciferase acts as an experimental reporter with constitutively active red firefly as a normalization control
  • This reporter-and-control combination enables simultaneous monitoring of experimental reporter and control luciferase activities in a single-read assay without the need for two-step addition of substrate reagents or quenching
  • The assay working solution contains substrates for both luciferases, and the reactions occur simultaneously with flash-type kinetics
  • The resulting luminescent signals are spectrally resolvable using filters
  • In a single sample, researchers can assay transcriptional activity of regulatory elements, signal transduction pathways, and effects of activators or inhibitors
  • Highlights: Simultaneous – concurrent, filter-based, wavelength-separated detection of two luciferase activities Sensitive – measure bright blue Cypridina and red firefly luciferase activities in the same sample Fast – no quenching step required, unlike in traditional sequential dual assays Multiplex – capable of quantitating two cellular activities in the same sample(s) Includes: Cell lysis buffer, reaction buffer, and substrates Vargulin and D-luciferin Requires: Cypridina and Red Firefly luciferase reporters; Filter sets in the ranges of 425 to 525nm for Cypridina Luc and 615 to 675nm for Red Firefly Luc
  • Luminometer or other instrument capable of monitoring luminescence, such as Thermo Scientific Luminoskan Ascent and Varioskan Flash Microplate Readers; Injector required for assessing more than 24 wells at a time
  • Recommended for: Study two regulatory elements at the same time; Monitor two signaling pathways simultaneously; Enable studying more than one target per screen (e.g
  • off-target effects)